Our standard regasification units are designed to operate when sea water is filtered and pumped as heating medium to the Unit heat sources.​

Since this heat source is at relative low temperature (assumed minimum design sea water temperature is 15°C) intermediate dry heat transfer fluid will be used between sea water and vaporizing LNG to avoid possible freezing inside the exchangers. The type of intermediate is selected upon the specific case and among easily available heat transfer fluids and glycol-water mixtures.